e0030 · e0030_merged · pick_up_bottle
A 17.33 s teleoperation episode — xArm6 carrying a BrainCo Revo2, driven by UDEX gloves through PICO. The simulated replay, the two cameras and the glove tactile are all indexed off the same 30 Hz grid, so one scrubber moves every pane to the same instant. The provenance notes at the bottom say what this episode is and is not good for.
| stream | samples | measured Hz | aligned | hole frames | max gap ms |
|---|---|---|---|---|---|
| arm_right | 1193 | 29.91 | 97.9% | 11 | 23.2 |
| depth_head | 522 | 30.0 | 100.0% | 0 | 2.4 |
| hand_right | 1560 | 41.23 | 93.7% | 33 | 40.8 |
| imu | 3911 | 201.49 | 100.0% | 0 | 2.5 |
| pico | 3479 | 89.98 | 96.4% | 19 | 37.2 |
| rgb_head | 522 | 30.0 | 100.0% | 0 | 2.4 |
| tactile_left | 592 | 28.53 | 97.9% | 11 | 17.9 |
| tactile_right | 593 | 28.51 | 98.5% | 8 | 17.9 |
| wrist_left | 523 | 29.99 | 100.0% | 0 | 4.6 |
| wrist_right | 523 | 30.0 | 100.0% | 0 | 1.1 |
| finger | status_ok | peak normal N |
|---|---|---|
| thumb | 27.5% | 0.000 |
| index | 0.0% | 2.010 · never reported |
| middle | 100.0% | 0.100 |
| ring | 90.6% | 2.130 |
| pinky | 100.0% | 1.270 |
Provenance. QC gate PASS — 0 fail, 9 warn, 45 pass. The operator marked the run a success. Judge training-worthiness from the gate and the stream table, not from this preview.
The gloves are on the operator, not the robot. The hand heatmaps are the human's side of the interaction (left peak 0.0186 N, right peak 1.5003 N); the pads that actually touch the object are the Revo2's, and those live only in raw/*/hand.jsonl — see the fingertip-pad table.
The cross-host clock offset is measured but approximate. Correlating arm motion against wrist-camera motion puts the offset at +5033.3 ms (correlation 0.289 against 0.038 at zero lag, resolution 90 ms), and the estimate is marked not confident — the peak is shallow. Camera frames in this page can therefore sit a few frames off the robot-state timeline.
The simulation pane is approximate in one known way.
The flange→hand mount rotation was set by matching the cameras
(180° about the tool axis — palm down, thumb on the base's +y side, verified
against the head and wrist cameras 2026-08-25), but the adapter plate's
translation is still unmeasured: the Revo2 base is drawn seated flat on the
flange face, so the plate's thickness is missing. The joint angles themselves are the
recorded ones, pushed through this machine's factory-calibrated kinematics.
rgb_head is a static table camera despite the name, and the wrist camera
is bolted to the robot flange.